Approvals

Confirmation of the effectiveness of Tytancoat:

Research of the Central Institute for Labor Protection: Study of the emission of nanoparticles during the processes of spray application of protective layers from an aqueous solution of nano titanium dioxide

  • PZH approval Virucidal
  • activity including SARS-CoV2 according to the EN 14476: 2019 method Virucidal activity on the material against influenza A H1N1 (A / PR / 8/34) virus from MDCK in accordance with ISO 18184: 2014 (E)
  • Virucidal activity on a plastic surface against influenza A H1N1 virus (A / PR / 8/34) from the ATCC VR-1469 collection in accordance with ISO 21702: 2019
  • Test for non-toxicity in accordance with FHSA regulation 16 CFR 1500.3
  • Test for non-toxicity in accordance with US FHSH 16 CFR 1500.41
  • Bactericidal activity against Legionella pneumophila according to the method of JIS L 1902: 2008
  • Bactericidal activity against Listeria monocytogenes according to the method of JIS L 1902: 2008
  • Bacteriological activity against methicillin resistant Staphylococcus aureus ATCC 33591 according to the method of JIS L 1902: 2008
  • Test of the antibacterial properties of the coated nonwoven fabric against Salmonella typhimurium AA 1.1194 according to the ISO 20743: 2013 method
  • Bactericidal activity against Alpha haemolytic Streptococcus (CMCC 32213) according to method ISO 20743: 2013
  • NOx removal efficiency from air according to ISO method 22197-1: 2016
TYTAN COAT Bacto-Vir Shield
Antimicrobial activity
Test organism Office lighting conditions
Inoculum concetration

(CFU/ml)

The value of bacteriostatic activity after 24 h Bacteriostatic value (%)
Staphylocococcus aureus (MRSA) ATCC33591

Methicillin resistant staphylococcus auresu

1.1x 105 >6.1 >99.9999%
Escherichia coli

ATCC8739

1.7X105  >6.6 >99.99997%
Listeria monocytogenes 54001 2.7×105  >3.8 >99.98%
Legionella pneumophila

ATCC33152

2.3×105 >5.2 >99.999%
Salmonella typhimurium

AS.1.1194

1.3×105  >5.8 >99.9998%
Alpha Hemolytic Streptococcus

CMCC 32213

1.2×105 >6.2 >99.9999%
Klebsiella pneumoniae

ATCC 4352

2.9×105 >6.3 >99.9999%
ISO 20743:2013/JIS L1902:2008 Certified by SGS Grupe
Results from the test on ceramic plate
 

 

Test organism

Oświetlone 40W fluorescencyjną w czasie testu
0 Hour

(cfu/ml)

 

24 hour

(cfu/ml)

Bacteriostatic value (%)
Escherichia coli

ATCC 25922

3.9×104 9.0×102 97.69
Staphylococcus auresu

ATCC 6538

6.8×103 1.1×102 98.38
Pseudomonas aerugimosa

ATCC 9027

2.8×105 84 99.97
Klebsiella pneumoniae 2.7×105 1.5×103 99.44
GB15979-2002 Cerfified by Guangdong National Microorganism Detection Center
Grzyby
Aspergillus Niger

ATCC 6275

2.3×105 >4.7 99.988
Antimicrobial activity under the influence of the various light intensities
Tested microorganism Xanthomonas Perforans
The intesity of the light Bacteriostatic value in (%)
30000 Lux >99.99999%
1200 Lux >99.95%
300 LUX >99.9%
No lighting >65%
Viruses
Tested virus The amount of virus Reduction
Vacciniavirus (Elstree) 6,95 +/- 0,39 ml ≥4,62 +/- 0,39
Transmissible Gastroenteritis Virus of Swine (TGEV, Toyama 36) 6,43 +/- 0,25 ml ≥4,10 +/-0,25
Eurovir  Hygiene-Labor GmbH metoda DIN EN 14476:2019
Influenza A virus; A/PR/8/34 (H1N1) ATCC VR-1469 2.10 x 107 4.3
NQEC Nissenken Quality Evaluation Center, Tokyo ISO21702:2019