Approvals
Confirmation of the effectiveness of TC:
Research of the Central Institute for Labor Protection: Study of the emission of nanoparticles during the processes of spray application of protective layers from an aqueous solution of nano titanium dioxide
- PZH approval Virucidal
- activity including SARS-CoV2 according to the EN 14476: 2019 method Virucidal activity on the material against influenza A H1N1 (A / PR / 8/34) virus from MDCK in accordance with ISO 18184: 2014 (E)
- Virucidal activity on a plastic surface against influenza A H1N1 virus (A / PR / 8/34) from the ATCC VR-1469 collection in accordance with ISO 21702: 2019
- Test for non-toxicity in accordance with FHSA regulation 16 CFR 1500.3
- Test for non-toxicity in accordance with US FHSH 16 CFR 1500.41
- Bactericidal activity against Legionella pneumophila according to the method of JIS L 1902: 2008
- Bactericidal activity against Listeria monocytogenes according to the method of JIS L 1902: 2008
- Bacteriological activity against methicillin resistant Staphylococcus aureus ATCC 33591 according to the method of JIS L 1902: 2008
- Test of the antibacterial properties of the coated nonwoven fabric against Salmonella typhimurium AA 1.1194 according to the ISO 20743: 2013 method
- Bactericidal activity against Alpha haemolytic Streptococcus (CMCC 32213) according to method ISO 20743: 2013
- NOx removal efficiency from air according to ISO method 22197-1: 2016
TC Bacto-Vir Shield | |||||||
Antimicrobial activity | |||||||
Test organism | Office lighting conditions | ||||||
Inoculum concetration
(CFU/ml) | The value of bacteriostatic activity after 24 h | Bacteriostatic value (%) | |||||
Staphylocococcus aureus (MRSA) ATCC33591
Methicillin resistant staphylococcus auresu | 1.1x 105 | >6.1 | >99.9999% | ||||
Escherichia coli
ATCC8739 | 1.7X105 | >6.6 | >99.99997% | ||||
Listeria monocytogenes 54001 | 2.7×105 | >3.8 | >99.98% | ||||
Legionella pneumophila
ATCC33152 | 2.3×105 | >5.2 | >99.999% | ||||
Salmonella typhimurium
AS.1.1194 | 1.3×105 | >5.8 | >99.9998% | ||||
Alpha Hemolytic Streptococcus
CMCC 32213 | 1.2×105 | >6.2 | >99.9999% | ||||
Klebsiella pneumoniae
ATCC 4352 | 2.9×105 | >6.3 | >99.9999% | ||||
ISO 20743:2013/JIS L1902:2008 Certified by SGS Grupe | |||||||
Results from the test on ceramic plate | |||||||
Test organism | Oświetlone 40W fluorescencyjną w czasie testu | ||||||
0 Hour
(cfu/ml)
| 24 hour
(cfu/ml) | Bacteriostatic value (%) | |||||
Escherichia coli
ATCC 25922 | 3.9×104 | 9.0×102 | 97.69 | ||||
Staphylococcus auresu
ATCC 6538 | 6.8×103 | 1.1×102 | 98.38 | ||||
Pseudomonas aerugimosa
ATCC 9027 | 2.8×105 | 84 | 99.97 | ||||
Klebsiella pneumoniae | 2.7×105 | 1.5×103 | 99.44 | ||||
GB15979-2002 Cerfified by Guangdong National Microorganism Detection Center | |||||||
Grzyby | |||||||
Aspergillus Niger
ATCC 6275 | 2.3×105 | >4.7 | 99.988 | ||||
Antimicrobial activity under the influence of the various light intensities | |||||||
Tested microorganism Xanthomonas Perforans | |||||||
The intesity of the light | Bacteriostatic value in (%) | ||||||
30000 Lux | >99.99999% | ||||||
1200 Lux | >99.95% | ||||||
300 LUX | >99.9% | ||||||
No lighting | >65% | ||||||
Viruses | |||||||
Tested virus | The amount of virus | Reduction | |||||
Vacciniavirus (Elstree) | 6,95 +/- 0,39 ml | ≥4,62 +/- 0,39 | |||||
Transmissible Gastroenteritis Virus of Swine (TGEV, Toyama 36) | 6,43 +/- 0,25 ml | ≥4,10 +/-0,25 | |||||
Eurovir Hygiene-Labor GmbH metoda DIN EN 14476:2019 | |||||||
Influenza A virus; A/PR/8/34 (H1N1) ATCC VR-1469 | 2.10 x 107 | 4.3 | |||||
NQEC Nissenken Quality Evaluation Center, Tokyo ISO21702:2019 |